Water / Oil Bath
YLGH series
Category:
Water / Oil Bath
keywords:
Mixing device Blender Centrifuge Laboratory enclosure
During the chemical synthesis process, there is temperature control of both the process and the samples. There is also constant temperature control for the samples. Tests on electronic components and materials are conducted at different temperatures. The equipment that can be matched includes (flow analyzer, ultrasonic disintegrator, disperser, viscometer, rheometer, electrophoresis instrument, refractometer, polarimeter, triple high-pressure flat membrane, adsorption instrument, reaction vessel, thermogravimetric analyzer (TGA), fermentation tank, etc.).
Product Specification
Product Features:
- Water & oil dual-purpose: Temperature options: Ambient to 100℃ , Ambient to 200℃ .
- External circulation: The circulating pump delivers thermostatted liquid out of the tank to create a second constant temperature zone for external experimental vessels.
- Capacity: 6L, 10L, 15L, 20L, 30L, 50L. Custom non‑standard models are available upon request.
- Temperature Fluctuation: ±0.05℃
Technical Specifications:
Model | Product Description | Volume(L) | Inner tank Dimensions | Working tank opening |
| YLGH-5 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 6 | 275×190×120 | 180×140 |
| YLGH-5A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
| YLGH-5D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
| YLGH-10 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 10 | 275×195×180 | |
| YLGH-10A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
| YLGH-10D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
| YLGH-15 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 15 | 300×250×200 | 235×160 |
| YLGH-15A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-15D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-20 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 20 | 300×250×270 | |
YLGH-20A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-20D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-25 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 25 | 300×250×335 | |
YLGH-25A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-25D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-30 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 30 | 440×325×210 | 310×280 |
YLGH-30A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-30D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-40 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 40 | 500×340×240 | 350×300 |
YLGH-40A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-40D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-50 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 50 | 500×340×300 | |
YLGH-50A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-50D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-100 | Room temperature ~ 100; Readability: 0.001°,Temperature fluctuation: ±0.005° | 100 | 625×400×400 | 480×380 |
YLGH-100A | Room temperature ~ 200; Readability: 0.001°,Temperature fluctuation: ±0.005° | |||
YLGH-100D | Room temperature ~ 300; Readability: 0.001°,Temperature fluctuation: ±0.005° |
-
File size: 303.5KB
Prev
Next
Prev
None
Next